Make the next communication decision with evidence.

Start with the product, identify one difficult data path, then agree how to measure a useful result. These notes are written for equipment manufacturers and system integrators evaluating a local sensor link.

Choose the question you need to answer

Review a pipe-inspection equipment integration question →

Read the evidence alongside the explanation

Our evidence page separates company-reported field observations from product scope and applications awaiting evaluation. The 30-second product film and transcript explain the integration concept; the film is not a measured performance test.

These guides are company application notes based on the current product record. They are not an independent qualification report. Updated product statements require a matching hardware revision and source; application recommendations remain subject to engineering validation.

Evaluate enclosed equipment in its intended conditions

How could pool equipment report status to a poolside controller?

Define the status message and interval, power both compatible endpoints, and record the closed housing, pool conditions, equipment orientation and reader position. Compare a dry baseline with operation in the intended pool setup. Log received messages and interruptions while the equipment runs.

Confirm the enclosure and pressure requirements separately. Read the current evidence for candidate water applications.

Can a nearby reader receive data from inside a sealed equipment housing?

Map the locations of the sensor and receiver, metal type and thickness, seams, end caps, openings and any existing feedthroughs. Compare receiver results at fixed positions with the proposed enclosure closed and under a reference condition. Record message delivery and changes to the setup.

Reception outside the enclosure establishes an observation for that geometry. The signal path through the wall, seams or end caps requires a separate test. Use the evaluation checklist to record the setup and results.

How can a pool-cleaning robot send status data to a poolside controller?

Evaluate Link Data for small status messages between the powered robot-side terminal and a compatible powered poolside reader. Test with the intended closed housing, water conditions and operating equipment. If orientation varies, discuss Vector Data and compare delivery across those orientations.

Prepare a Link Data evaluation brief

Can a sensor inside a sealed metal housing send data to an external reader?

Link Data is a configuration to evaluate for a small sensor message to a compatible powered reader. Record the housing material, thickness, seams, openings and both terminal positions. Test the closed assembly and document the possible signal paths and message delivery for that exact geometry.

Prepare a Link Data evaluation brief

Discuss one sensor communication task.

Email a non-confidential outline with what needs to communicate, the current link problem, the installation and the data you need. Our team will review the application and discuss a useful next step. Response time and project scope are agreed separately.

Email hello@magdatix.com